Think of your typical porous bare silica support as a big sponge full of holes. All of those holes (pores) are where the sample will migrate through before emerging out the other side. With conventional chromatography supports, most of the interaction takes place inside the particle, not on the surface. The size and number of these openings relate to retention time. Besides particle size (particle diameter), pore size is one of the most important characteristics of silica based chromatography supports.
The pore size or pore diameter is often expressed in Angstroms (i.e. 80 A = 8 nm). The degree of porosity relates to the hydrodynamic volume of your sample and is inversely related to the surface area of the support. The larger the surface area of the support (smaller pore size), the longer the possible retention of the sample. For small drug molecule samples under 1,000 daltons (an estimate only) we often use high surface area supports with small pore sizes between 60 and 150 Angstroms (~ 200 to 500 square meters per gram). These provide high retention characteristics useful in separating apart many small compounds in one analysis run. For larger molecules (i.e. peptides and proteins), we employ supports with larger pore sizes (~300 Angstroms). Particles with small pores have larger surface areas which can provide more interaction with the sample. Note: Pore size is often determined using the BET Nitrogen adsorption/desorption equation. Due to endcapping of the support (e.g. C8 or C18), the actual value obtained is often 20-30% less than the original value.
When comparing
bare silica columns or trying to identify similar conventional columns for use in a method, pore size must be considered. Manufacturer's publish the pore size in Angstroms (*sometimes in nm) for their different supports. Choosing columns with similar pore sizes is just one of many parameters needed to provide similar retention characteristics.
The HPLC "Hints and Tips" found here will be of interest to anyone performing HPLC, UHPLC (UPLC), LC/MS, SFC, CE or GC analysis. Many of these free tips, taken from professional classes that I teach, discuss fundamental to advanced level chromatography concepts in a practical way. Occasionally, I will also include laboratory computer related tips here too. Please "follow" this blog to receive updates of new posts. Hint: Type keywords into the SEARCH bar to quickly find other articles.
Translator for HPLC HINTS and TIPS for Chromatographers
Showing posts with label Hints. Show all posts
Showing posts with label Hints. Show all posts
Saturday, December 20, 2014
Tuesday, June 19, 2012
HPLC Hints & Tips Web Page
If you would like to see some of these tips in a tabular format on a single web page, then check out this link:
HPLC HINTS & TIPS for
Chromatographers:
http://www.hplctools.com/hplc_hints_tips.htm
HPLC BLOG link, which is updated more frequently, can be found here:
http://hplctips.blogspot.com/
Note: The web page and blog versions present some of the same tips, but some of the tips are only shown on one or the other page so it pays to check them both to stay up-to-date on all of the tips offered.
Labels:
Calculation,
CHIRAL,
Chiralizer,
Consulting,
Diode Array Detector,
Hints,
HPLC,
Method Development,
Repair,
Services,
SFC,
Tips,
Troubleshooting,
UHPLC,
UPLC,
Web Site,
William Letter
Subscribe to:
Posts (Atom)